Brand New  Endress+Hauser FMU40 Series Radar Level Detector Anti Corrosion Radar Level Gauge

Brand New Endress+Hauser FMU40 Series Radar Level Detector Anti Corrosion Radar Level Gauge
FMU40 is suitable for non-contact level measurement of liquids, slurries, and solid blocks, as well as flow measurement of open channels or measuring weirs. Two wire or four wire integrated transmitters can be used for complex working conditions such as storage tanks, mixers, silos, and conveyors. The on-site envelope display can be used for simple instrument fault diagnosis. The linearization function (up to 32 points) can convert measurement values into any unit of length, volume, or flow rate.
Download Attachment
Whatsapp : +86 17391983629‬
Email : Jayna@xinyiyb.com
CONTACT US

Product Description

Product Description

Prosonic  FMU40  is suitable for non-contact level measurement of liquids, slurries, and solid blocks, as well as flow measurement of  open channels or measuring weirs. Two wire or four wire integrated transmitters can be used for complex working  conditions such as storage tanks, mixers, silos, and conveyors. The on-site envelope display can be used for simple  instrument fault diagnosis. Linearization function (up to 32 points) can convert measurement values into any unit of  length, volume, or flow rate.


Core Technology and Specifications

  1. Measurement accuracy: ± 2 mm or ± 0.2% of the set range;

  2. Maximum measurement distance: 5 meters for liquid media and 2 meters for solid media. Higher models in the same      series (FMU41 to FMU44) can provide a larger range;

  3. Process conditions: The process temperature range is -40 ° C to+80 ° C, and the process pressure (absolute) range      is 0.7 to 3 bar abs;

  4. Main liquid receiving components: PVDF material, with good chemical corrosion resistance;

  5. Communication and power supply: Supports two-wire or four wire systems, integrated with HART protocol.      Simultaneously optional PROFIBUS PA or Foundation fieldbus (FF) communication;      


Advantage

  • Four line pure text display, menu guided on-site operation, quick and simple instrument debugging, available in 7      languages;

  • On site envelope display, complete simple instrument fault diagnosis;

  • Provide FieldCare operation software, allowing users to easily remotely operate instruments, diagnose faults, and      compile measurement point files;

  • Suitable for explosion hazardous areas (gas Ex, dust Ex);

  • The linearization function (up to 32 points) can convert measured values into lengths, volumes, or flow rates in      any unit;

  • Built in temperature sensor, automatically corrects the speed of sound affected by temperature;

  • Optional remote display and operation (maximum installation distance from transmitter can reach 20m (66ft));


Technical Parameters:

ApplicationTransmissor ultrasônico compacto
Power supplyTwo wire/four wire system (HART)
Measurement accuracy+/- 2mm
Ambient temperature-40...80 °C
Process temperature-40...80 °C
Main liquid receiving componentsPVDF
Process connectionG / NPT 1 1/2"
Blind spot distance0.25 m
Communication4 ... 20 mA HART
Certificates and certificationsATEX、FM、CSA、TIIS、INMETRO、NEPSI


IMG20240422153141

IMG20240422153054

cindy.png